Sie sind Besucher Nr.
gratis Counter by GOWEB
seit dem 30.10.2007

      
Construction Systems
Marketing Ltd.
Postfach 3075
64614 Bensheim
Tel.:06251 - 790890
    
        Ü-Zeichen

Bearing of thermal bridges

Insulatet sandwich - panel with traditionel steel - ties

Platzhalterbild

 

 

 

 

 

 

 

 

 

 

Thermal transmission in insulated area: U=0.55 W/m²K

Thermal transmission around  tie: U= 4.10 W/m²K

Average thermal transmission through panel: U= 1.58 W/m²K

Insulatet sandwich - panel with THERMOMASS - system

Platzhalterbild

 

 

 

 

 

 

 

 

 

 

Thermal transmission in  insulated area: U=0.55 W/m²K

Thermal transmission around conncetor: U= 1.86 W/m²K

Average thermal transmission through panel: U= 0.60 W/m²K

The average thermal transmission of a well insulated sandwich panel with steel ties is more than two and a half times greater than that of a panel with THERMOMASS connectors. The transmission rate ist sustantially worse in panels which are not insulated and have concrete seams with metal re-inforcements linking the layers. ONLY the THERMOMASS system ensures that 99 % of the design value of the thermal insulation performance of a building can be achieved.